High-Performance Flame-Retardant Engineering Sealant

Release Date:2026-01-13 Page Views:235
High-Performance Flame-Retardant Engineering Sealant

Building silicone sealant is currently the most widely used waterproof and sealing material in interior and exterior decoration of buildings. Compared with ordinary building silicone sealants, flame - retardant silicone sealants have the characteristics of less smoke, non - toxicity during combustion, low heat of combustion, and slow flame spread rate. They are suitable for flame - retardant sealing in fire - resistant doors and windows, curtain wall projects, and various other construction projects.
The national standards specify the technical properties of GB 16776 - 2005 "Silicone Structural Sealants for Building" and GB 24267 - 2009 "Flame - Retardant Sealants for Building". However, in actual construction, due to complex and harsh working conditions, higher requirements are put forward for its flame - retardant and other properties. There is simply no V - 0 grade product on the market, or the products cannot meet the requirement of fluidity (leveling time of 5 minutes).
Our company has developed a high - performance flame - retardant engineering sealant, which has overcome the harsh construction requirements, and its performance far exceeds the national standard's top - grade products.

Technical characteristics


Item

GB/T 9756

ASTM C 1184

This Technology*

Differences

Sag

Vertical placement / mm

≤ 3

≤ 4.8

≤ 3

Indicator value difference

Horizontal placement

No deformation

No deformation

No deformation

Extrudability / s

≤ 10

≤ 10

≤ 10

-

Service life / mm (two-component only)

≥ 20

-

≥ 20

-

Tack-free time / h

≤ 2

≤ 2

≤ 1

Indicator value   difference

Hardness (Shore A)

20~60

20~60

20~60

-

Tensile Adhesion

Adhesion Strength /   MPa

Standard conditions

≥ 0.60

≥ 0.345

≥ 0.60

a) Indicator value   difference;

b) Tensile speed 6   mm/min (C1184 is 12 mm/min);

c) Water-UV light   exposure test uses UV-light + hot water conditions (C1184 uses UV-light +   condensation conditions)

90°C

≥ 0.45

≥ 0.345

≥ 0.45

-30°C

≥ 0.45

≥ 0.345

≥ 0.45

After water immersion

≥ 0.45

≥ 0.345

≥ 0.45

After water-UV light   exposure

≥ 0.45

≥ 0.345

≥ 0.45

Adhesive failure area / %

5

-


Maximum elongation at   23°C / %

≥ 100

-


Thermal Aging

Weight loss / %

≤ 10

≤ 10

≤ 10

-

Crazing

None

None

None

-

Chalking

None

None

None

-

*This Technology:   Flow time 5 minutes and flame retardancy V-0 grade (after two 10-second flame   application tests, the flame extinguishes within 30 seconds with no burning   drips).